3263-5-A-250-1-60

Circuit Breakers

CIRCUIT BREAKER

3263-5-A-250-1-60

5925-00-356-0746

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    2.677 inches minimum and

  • Body Height

    2.697 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.369 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.994 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 threaded hole and

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Circuit Protection Type

    overcurrent first location

  • Circuit Protection Type

    overcurrent second location

  • Trip Release Method

    magnetic-hydraulic first location

  • Trip Release Characteristic

    time delay first location

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip first location

  • Nominal Thread Size

    0.164 inches

  • Switch Location And Position Designation

    external at pole three

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 maximum at 200 pct first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    38.000 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    dustproof and

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Switch Terminal Type

    threaded stud

  • Special Features

    pole three is a switch only

  • Frequency In Hertz

    60.0 all locations

  • Thread Series Designator

    unc

  • Body Style

    11b multipole-single actuator type

  • Body Length

    5.240 inches minimum and

  • Body Length

    65.260 inches maximum

  • Body Width

    2.990 inches minimum and

  • Body Width

    3.010 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    0.974 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.994 inches maximum

  • Boss Height

    0.208 inches minimum and

  • Boss Height

    0.228 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Trip Release Method

    magnetic-hydraulic second location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Auxiliary Switch Function And Quantity

    1 control

  • Internal Trip Release Configuration

    series trip second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 maximum at 200 pct second location

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...