Technical Characteristics
-
Reliability Indicator
not established
-
Mounting Hole Diameter
0.157 inches nominal single group
-
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
-
Body Width
1.000 inches maximum
-
Inclosure Type
open
-
Mounting Facility Quantity
2 single group
-
Winding Function And Quantity
1 primary and 1 secondary single component
-
Winding Tap Location
multiple taps w/o center tap single component single secondary
-
~1
ac maximum single component single secondary
-
Winding Operating Current
480.0 milliamperes ac maximum and 680.0 milliamperes ac maximum and 1.0 amperes
-
~1
component single secondary
-
Terminal Type And Quantity
6 tab, solder lug
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Length
1.500 inches maximum
-
Body Height
1.750 inches maximum
-
Distance Between Mounting Facility Centers
1.250 inches nominal single mounting facility single center group
-
Mounting Method
flange and unthreaded hole single group
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Voltage
4.05 ac volts nominal and 5.80 ac volts nominal and 8.50 ac volts nominal single