SU1000-1

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

SU1000-1

5915-00-376-9014

5915 - Filters and Networks

Bae Systems Information And

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Voltage Drop Per Function

    1.2 volts ac 1st radio interference

  • Operating Temp Range

    -28.0/+75.0 deg celsius

  • Body Surface Treatment

    tin

  • Functional Terminal Type And Quantity

    2 tab w/screw input 1st function

  • Source Impedance Rating Per Function

    20.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Body Material

    metal

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Functional Terminal Type And Quantity

    2 tab w/screw output 2nd function

  • Source Impedance Rating Per Function

    20.0 ohms 2nd radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 2nd radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Load Impedance Per Function

    20.0 ohms 2nd radio interference

  • Overall Length

    5.625 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Operating Current Rating Per Function In Amps

    20.0 2nd radio interference

  • Load Impedance Per Function

    20.0 ohms 1st radio interference

  • Mounting Facility Type And Quantity

    4 terminal

  • Inclosure Type

    hermetically sealed

  • Overall Height

    1.344 inches nominal

  • Operating Current Rating Per Function In Amps

    20.0 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Body Length

    4.156 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Body Width

    3.000 inches nominal

  • Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...