4100-35
Coils and Transformers
COIL,RADIO FREQUENCY
4100-35
American Precision Industries Inc
COIL,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Coil Form Type
hollow
-
Core Construction
powdered
-
Body Length
0.952 inches maximum
-
Inclosure Type
fully inclosed
-
Rating Method
electrical
-
Winding Operating Current
182.0 milliamperes dc maximum
-
Dc Resistance Rating In Ohms
4.500
-
Quality Factor
70 minimum and 85 maximum
-
Frequency At Which Inductance And Quality Factor Applies
790.0 kilohertz
-
Adjustment Method And Quantity
1 adjustable core
-
Inductance Rating
120.00 microhenries minimum and 290.00 microhenries maximum
-
Adjustment Device Drive Type
shaft
-
Body Outside Diameter
0.400 inches nominal
-
Mounting Method
terminal
-
Terminal Type And Quantity
2 pin