2263-10-250AC1-60HZ

Circuit Breakers

CIRCUIT BREAKER

2263-10-250AC1-60HZ

5925-00-387-5508

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    9b multipole-single actuator type

  • Body Length

    5.188 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one and two linked

  • Nominal Thread Size

    0.190 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum all locations

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unf

  • Trip Delay Time In Seconds Per Rated Continuous Current

    400.000 maximum at 125 pct and 100.000 maximum at 200 pct all locations

  • Terminal Type And Quantity

    2 threaded stud

  • Body Width

    2.000 inches nominal

  • Body Height

    2.641 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Boss Height

    0.219 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    2 threaded stud

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Internal Trip Release Configuration

    series trip all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...