Technical Characteristics
-
Contact Action Stimulus
increase
-
Thread Quantity Per Inch
20 single pressure connection
-
Outside Diameter
0.438 inches nominal single connection
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Sensing Element Burst Pressure
3000.00 pounds per square inch
-
Terminal Type
wire lead
-
Pressure Switch Type
gage
-
Contact Load Current Rating
5.0 amperes resistive load single voltage and 2.0 amperes inductive load single voltage and 1.0 amperes lamp load single voltage
-
Nominal Thread Size
0.438 inches single pressure connection
-
Pressure Connector Type
flared, threaded external single connection
-
Media For Which Designed
gas or liquid
-
Thread Class
3a single pressure connection
-
Overall Length
1.785 inches minimum and 1.815 inches maximum
-
Overall Diameter
0.675 inches maximum
-
Features Provided
hermetically sealed case
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 275.0 deg fahrenheit maximum
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Mounting Method
clamp
-
Hazardous Locations/Environmental Protection
weatherproof
-
Body Length
1.250 inches maximum
-
Proof Pressure
750.00 pounds per square inch
-
Width Across Flats
0.745 inches minimum and 0.750 inches maximum
-
Err Default
err default
-
Style Designator
cylindrical
-
Contact Stimulus Rating
120.00 differential point nominal pounds per square inch gage