ETN43

Circuit Breakers

CIRCUIT BREAKER

ETN43

5925-00-396-2339

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-17361 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Body Length

    10.000 inches maximum

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • ~1

    data on certain environmental and performanc

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    8.750 inches nominal

  • Actuator Function

    trip-reset

  • Special Features

    circuit breaker supplied with four 1/4-20 mounting screws 1.812 in. lg

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.625 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 600 pct all locations and 45.000 maximum at 600 pct all locations

  • Arc Quenching Method

    air

  • Body Width

    5.000 inches maximum

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Specification/Standard Data

    81349-mil-c-17361 government specification

  • Manual Actuator Type And Quantity

    1 toggle

  • Mounting Surface To Terminal End Distance

    8.407 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.750 inches nominal

  • Boss Height

    0.125 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.438 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.625 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    7500.0 ac all locations and 10000.0 dc all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...