40912
Coils and Transformers
TRANSFORMER,POWER
40912
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.250 inches nominal
-
Frequency Rating
57.0 hertz minimum and 420.0 hertz maximum
-
Mounting Method
threaded stud
-
Winding Function And Quantity
1 primary and 2 secondary
-
Winding Operating Current
25.0 milliamperes ac maximum
-
Winding Operating Current
450.0 milliamperes ac maximum
-
Winding Operating Voltage
22.00 ac volts nominal
-
Winding Operating Voltage
42.00 ac volts nominal
-
Thread Series Designator
unc
-
Thread Class
2a
-
Thread Direction
right-hand
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.438 inches nominal
-
Input-Output Phase Relationship
single phase to single phase
-
Body Length
2.062 inches nominal
-
Body Width
1.656 inches nominal
-
Body Height
1.688 inches nominal
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.138 inches
-
Winding Operating Current
150.0 milliamperes ac maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Terminal Type And Quantity
6 wire lead