1AP112R191-6
Circuit Breakers
CIRCUIT BREAKER
1AP112R191-6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Body Width
1.937 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac second location
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Body Length
1.562 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Unpackaged Unit Weight
5.400 ounces
-
Terminal Type And Quantity
6 wire hook
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations
-
Bushing Length
0.380 inches maximum
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
-
Inclosure Protection Type For Which Designed
hermetically sealed and moisture resistant and shock resistant and salt spray proof
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Switch Location And Position Designation
internal at pole two
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac third location
-
Trip Release Method
magnetic-hydraulic all locations
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Actuator Position Designation
at pole two
-
Switch Contact Arrangement
single pole, double throw
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 50.0 dc all locations
-
Body Style
multipole-single actuator type