LS9192-6-2

Switches

SWITCH,ROTARY

LS9192-6-2

5930-00-401-6724

5930 - Switches

Lockheed Martin Corporation

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.251 inches maximum single actuator

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Throw Quantity

    6 each section front

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Contact Load Current Rating

    1.0 amperes resistive load dc at sea level

  • Thread Series Designator

    unc single mounting facility

  • Pole Quantity

    1 each section front

  • Nonturn Device Type

    slotted bushing at 3:00 o'clock

  • Individual Section Quantity

    2

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Contact Load Current Rating

    500.0 milliamperes resistive load dc at altitude

  • Contact Switching Action

    breaks before makes each section front

  • Shaft Flat/Slot Angular Location

    225.0 degrees from nonturn device single actuator

  • Flat Height

    0.211 inches minimum single actuator and 0.221 inches maximum single actuator

  • Switch Actuator Indexing Position Quantity

    6 single actuator

  • Nonturn Device Radius

    0.432 inches nominal at 3:00 o'clock

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Err Default

    err default

  • Style Designator

    tap, circular, bushing mount

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Shaft Type

    round, flatted single actuator

  • Overall Diameter

    1.036 inches maximum

  • Hazardous Locations/Environmental Protection

    explosion proof

  • Mounting Method

    threaded bushing single mounting facility

  • Overall Length

    2.132 inches minimum and 2.272 inches maximum

  • Thread Quantity Per Inch

    32 single mounting facility

  • Thread Class

    2a single mounting facility

  • First Flat Length

    0.245 inches minimum single actuator and 0.255 inches maximum single actuator

  • Terminal Type

    tab, solder lug

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Shaft Length

    0.864 inches minimum single actuator and 0.884 inches maximum single actuator

  • Contact Load Current Rating

    2.0 amperes resistive load ac at sea level

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...