3363SMG4-50-250VAC2BS

Circuit Breakers

CIRCUIT BREAKER

3363SMG4-50-250VAC2BS

5925-00-401-7610

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    2.682 inches minimum and 2.692 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    2.927 inches minimum and 2.937 inches maximum

  • Body Length

    5.245 inches minimum and 5.255 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.185 inches minimum and 0.195 inches maximum

  • Boss Height

    0.577 inches minimum and 0.587 inches maximum

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    explosion proof and vibrationproof and shock resistant and fungus resistant and moisture resistant

  • Frequency In Hertz

    60.0 all locations

  • Unpackaged Unit Weight

    1.800 pounds

  • Body Style

    11b multipole-single actuator type

  • Body Width

    2.995 inches minimum and 3.005 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.995 inches minimum and 2.005 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.354 inches minimum and 4.364 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.995 inches minimum and 1.005 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct

  • Precious Material And Location

    contact surfaces silver

  • Precious Material

    silver

  • Terminal Type And Quantity

    6 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...