3363SMG4-15-250-2-60

Circuit Breakers

CIRCUIT BREAKER

3363SMG4-15-250-2-60

5925-00-401-7687

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 compression

  • Precious Material

    silver

  • Precious Material And Location

    contact surfaces silver

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Actuator Position Designation

    at pole two

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Circuit Protection Type

    overcurrent all locations

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.488 inches minimum and 0.515 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.995 inches minimum and 1.005 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    2.818 inches minimum and 2.848 inches maximum

  • Unpackaged Unit Weight

    1.800 pounds

  • Frequency In Hertz

    60.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct all locations and 19.000 maximum at 200 pct

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Boss Height

    0.203 inches minimum and 0.233 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.344 inches minimum and 4.374 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Body Height

    2.672 inches minimum and 2.702 inches maximum

  • Case Material

    plastic

  • Body Width

    2.995 inches minimum and 3.005 inches maximum

  • Body Length

    5.235 inches minimum and 5.265 inches maximum

  • Body Style

    11b multipole-single actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...