7276-101-1 1/2

Circuit Breakers

CIRCUIT BREAKER

7276-101-1 1/2

5925-00-401-7702

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 35.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Special Features

    unlimited ac and dc interrupting current capacity

  • Body Style

    multipole-single actuator type

  • Unpackaged Unit Weight

    0.350 pounds

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nonturn Device Location

    at 3 oclock and at 9 oclock and at 6 oclock and at 12 oclock

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    0.703 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.375 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    2.000 inches maximum

  • Inclosure Protection Type For Which Designed

    explosion proof and shock resistant and vibration resistant

  • Body Width

    0.850 inches maximum

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Body Height

    2.765 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...