M39019-5-81

Circuit Breakers

CIRCUIT BREAKER

M39019-5-81

5925-00-402-3902

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct and 0.240 maximum at 400 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum all locations and 7.000 maximum

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.375 inches

  • Test Data Document

    81349-mil-c-39019 specification

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Bushing Length

    0.380 inches maximum

  • Body Width

    1.937 inches maximum

  • Case Material

    metal

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...