300109
Coils and Transformers
TRANSFORMER,POWER
300109
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Frequency Rating
50.0 hertz minimum single component and 400.0 hertz maximum single component
-
Nominal Thread Size
0.164 inches single group
-
Overall Height
4.000 inches nominal
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Terminal Type And Quantity
5 tab, solder lug
-
Reliability Indicator
not established
-
Body Width
2.810 inches nominal
-
Test Data Document
93024-300109 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal single mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Body Height
3.620 inches nominal
-
Thread Series Designator
unc single group
-
Body Length
3.120 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.125 inches nominal single mounting facility single center group
-
Inclosure Type
hermetically sealed with oil
-
Winding Operating Voltage