2817045
Coils and Transformers
TRANSFORMER,POWER
2817045
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
400.0 hertz nominal single component
-
Reliability Indicator
not established
-
Mounting Method
unthreaded hole single group
-
Winding Operating Voltage
60.00 ac volts nominal single component 1st secondary
-
Winding Operating Voltage
38.00 ac volts nominal single component 3rd secondary
-
Inclosure Type
partially inclosed, double shell
-
Mounting Hole Diameter
0.156 inches nominal single group
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Terminal Type And Quantity
11 tab, solder lug
-
Winding Operating Current
50.0 milliamperes dc maximum single component 1st secondary
-
Mounting Facility Quantity
4 single group
-
Winding Operating Current
250.0 milliamperes dc maximum single component 3rd secondary
-
Winding Operating Current
250.0 milliamperes dc maximum single component 2nd secondary
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Distance Between Mounting Facility Centers
0.937 inches nominal single mounting facility single center group and 0.937 inches nominal single mounting facility single center group
-
Body Length
1.312 inches nominal
-
Body Width
1.312 inches nominal
-
Winding Operating Voltage
38.00 ac volts nominal single component 2nd secondary
-
Body Height
1.562 inches nominal
-
Maximum Operating Temp
130.0 deg celsius
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Test Data Document