B505700001

Circuit Breakers

CIRCUIT BREAKER

B505700001

5925-00-406-4238

5925 - Circuit Breakers

Kearfott Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Internal Trip Release Configuration

    series trip first location

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Body Width

    2.245 inches minimum and 2.255 inches maximum

  • Internal Trip Release Configuration

    series trip third location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct all locations and 2.000 maximum at 200 pct all locations

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.745 inches minimum and 0.755 inches maximum

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    24.0 dc maximum second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal and remote trip feature second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Mounting Surface To Terminal End Distance

    1.835 inches minimum and 1.845 inches maximum

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Terminal Type And Quantity

    6 tab, solder lug

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Duty Cycle

    intermittent second location

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Trip Release Method

    magnetic-hydraulic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...