72-287-1

Circuit Breakers

CIRCUIT BREAKER

72-287-1

5925-00-406-6120

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Time Per Pole In Seconds

    1.500 minimum all locations and 6.000 maximum all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Switch Location And Position Designation

    external at pole one

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Auxiliary Switch Function And Quantity

    1 control

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Thread Series Designator

    unc

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    47.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Arc Quenching Method

    air

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Width

    2.240 inches minimum and 2.260 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...