1903-06
Coils and Transformers
TRANSFORMER,POWER
1903-06
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Class
2a
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.810 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.250 inches nominal
-
Frequency Rating
47.0 hertz minimum and 420.0 hertz maximum
-
Winding Shielding Method
internal shield grounded to core and brought out to terminal
-
Mounting Method
threaded stud
-
Winding Tap Location
center tap
-
Winding Operating Current
200.0 milliamperes ac maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Thread Direction
right-hand
-
Input-Output Phase Relationship
single phase to single phase
-
Body Length
3.380 inches nominal
-
Body Width
2.810 inches nominal
-
Body Height
2.560 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Winding Function And Quantity
2 primary and 3 secondary
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.164 inches
-
Winding Operating Current
2.0 amperes ac maximum
-
Winding Operating Voltage
34.00 ac volts nominal
-
Winding Operating Voltage
58.00 ac volts nominal
-
Thread Series Designator
unc
-
Terminal Type And Quantity
12 tab,solder lug