JA2A3B6A20-2

Circuit Breakers

CIRCUIT BREAKER

JA2A3B6A20-2

5925-00-408-5731

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.130 inches nominal

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • External Actuator Linkage Arrangement

    one and two linked

  • Body Width

    1.500 inches nominal

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Frequency In Hertz

    50.0 first location or 60.0 first location

  • Manual Actuator Type And Quantity

    2 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct second location and 7.000 maximum at 200 pct second location

  • Switch Contact Arrangement

    single pole, double throw

  • Internal Trip Release Configuration

    series trip first location

  • Body Style

    multipole-multiple actuator type

  • Arc Quenching Method

    air

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc second location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc second location

  • Mounting Surface To Terminal End Distance

    1.880 inches nominal

  • Body Length

    2.000 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct first location and 11.000 maximum at 200 pct first location

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Pole Quantity

    2

  • Internal Trip Release Configuration

    relay trip second location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...