Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    1.515 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct

  • Frequency In Hertz

    60.0 all locations

  • Unpackaged Unit Weight

    7.400 ounces

  • Thread Series Designator

    unc

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.625 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    7.4 amperes ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one and two linked

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...