13226E4361-1

Circuit Breakers

CIRCUIT BREAKER

13226E4361-1

5925-00-413-1210

5925 - Circuit Breakers

Cecom Lr Center

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Specification/Standard Data

    81348-w-c-375/5 government specification

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • End Item Identification

    nsn 4210-01-486-1035 tfft (tactical fire fighting truck)

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.732 inches minimum and 0.748 inches maximum

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Method

    thermal-magnetic single location

  • Boss Height

    0.188 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    1 compression and 1 clip

  • Body Height

    2.307 inches minimum and 2.317 inches maximum

  • Body Length

    2.987 inches minimum and 3.013 inches maximum

  • Body Style

    single pole type

  • Mounting Facility Type And Quantity

    2 terminal

  • Frequency In Hertz

    60.0 single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac single location

  • Case Material

    plastic

  • ~1

    data on certain environmental and performance re

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.