Technical Characteristics

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.800 minimum at 200 pct and 8.000 maximum at 200 pct

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Method

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Terminal Type And Quantity

    2 wire hook

  • Unpackaged Unit Weight

    1.800 ounces

  • Frequency In Hertz

    60.0

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Switch Terminal Type

    pin

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    150.0 milliamperes ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Fragility Factor

    moderately rugged

  • Case Material

    metal

  • Body Width

    0.625 inches maximum

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Thread Pitch Diameters

    p0.3503/p0.3537 inches

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Trip Release Characteristic

    time delay

  • Circuit Protection Type

    overcurrent

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...