6760-17-7 1/2

Circuit Breakers

CIRCUIT BREAKER

6760-17-7 1/2

5925-00-415-6106

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.250 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.728 inches minimum and 0.758 inches maximum

  • Thread Quantity Per Inch

    32

  • Iii Storage Type

    general purpose warehouse

  • Trip Release Method

    thermal all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.219 inches minimum and 1.557 inches maximum

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.203 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 tab w/screw

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Unpackaged Unit Weight

    8.000 ounces

  • Frequency In Hertz

    400.0 all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Thread Series Designator

    unc

  • Body Style

    2b multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus proof and humidity resistant and dusttight and sand resistant and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 70.000 maximum at 200 pct all locations

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Pole Quantity

    3

  • Case Material

    plastic

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Trip Release Characteristic

    time delay all locations

  • Body Width

    2.203 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Mounting Surface To Terminal End Distance

    2.125 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Manual Actuator Type And Quantity

    1 push-pull

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...