APL1-1-4-2-502M

Circuit Breakers

CIRCUIT BREAKER

APL1-1-4-2-502M

5925-00-417-2784

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Boss Height

    0.150 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and vibration resistant

  • Frequency In Hertz

    400.0 single location

  • Specification/Standard Data

    81349-mil-c-55629/1 government specification

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...