51MC2-123-12

Circuit Breakers

CIRCUIT BREAKER

51MC2-123-12

5925-00-417-3762

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Body Length

    2.015 inches maximum

  • Body Width

    0.745 inches minimum and

  • Body Width

    0.755 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.565 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.655 inches minimum and

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.875 inches minimum and

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct single location

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.665 inches maximum

  • Boss Height

    0.125 inches minimum and

  • Boss Height

    0.135 inches maximum

  • Mounting Surface To Terminal End Distance

    1.885 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Body Length

    1.985 inches minimum and

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    dustproof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...