151286-01
Coils and Transformers
TRANSFORMER,POWER
151286-01
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Overall Length
1.448 inches minimum and 1.458 inches maximum
-
Overall Height
1.000 inches nominal
-
Mounting Hole Diameter
0.126 inches minimum single group and 0.133 inches maximum
-
Frequency Rating
9.0 kilohertz minimum single component and 11.0 kilohertz maximum
-
Body Length
0.943 inches nominal
-
Body Width
1.265 inches minimum and 1.275 inches maximum
-
Body Height
0.770 inches minimum and 0.780 inches maximum
-
Maximum Operating Temp
130.0 deg celsius
-
Inclosure Type
fully inclosed
-
Mounting Method
unthreaded hole single group
-
Features Provided
color coded terminal
-
Winding Tap Location
center tap single component single primary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Distance Between Mounting Facility Centers
1.195 inches minimum single mounting facility single center group and 1.205 inches maximum
-
Mounting Method
plug-in single group and 2
-
Features Provided
tinned wire leads and and
-
Winding Tap Location
center tap single component single secondary
-
Winding Operating Current
2.0 amperes ac maximum single component single secondary
-
Winding Operating Voltage
110.00 ac volts nominal single component single primary
-
Winding Operating Voltage
33.20 ac volts nominal single component single secondary
-
Terminal Type And Quantity
6 wire lead