NJL631350R

Circuit Breakers

CIRCUIT BREAKER

NJL631350R

5925-00-419-3958

5925 - Circuit Breakers

Challenger Electrical Equipment Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.187 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    9.125 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.250 inches nominal

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Height

    4.312 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Maximum Continuous Load Current Rating Per Pole

    350.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Body Width

    8.250 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Length

    10.125 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.125 inches nominal

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    500.000 minimum at 200 pct all locations and 650.000 maximum at 200 pct all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...