SM-C-587306

Circuit Breakers

CIRCUIT BREAKER

SM-C-587306

5925-00-421-9915

5925 - Circuit Breakers

Us Army Communications &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac second location

  • Body Length

    1.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Internal Trip Release Configuration

    series trip first location

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.005 minimum at 200 pct third location and 0.017 maximum at 200 pct third location

  • Case Material

    metal

  • Internal Trip Release Configuration

    series trip second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct second location and 6.000 maximum at 200 pct second location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Body Width

    1.875 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Unpackaged Unit Weight

    4.800 ounces

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac second location

  • Reset Method

    manual

  • Terminal Type And Quantity

    6 wire hook and 2 tab, solder lug

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc third location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Internal Trip Release Configuration

    relay trip third location

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    50.0 dc third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct first location and 6.000 maximum at 200 pct first location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

  • Trip Release Method

    magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.