Technical Characteristics
-
Ultimate Trip Time Per Pole In Seconds
60.000 maximum all locations
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
relay trip fourth location
-
Internal Trip Release Configuration
series trip second location
-
Internal Trip Release Configuration
series trip third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 nominal at 150 pct first location
-
Switch Terminal Type
turret
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Test Data Document
17773-11207114 drawing
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc fourth location
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Mounting Facility Type And Quantity
8 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes dc fourth location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac third location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc fourth location
-
Trip Release Method
magnetic all locations
-
Trip Release Characteristic
instantaneous and time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
4 toggle
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Auxiliary Switch Function And Quantity
3 control
-
Internal Trip Release Configuration
series trip first location
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 nominal at 150 pct fourth location
-
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 nominal at 150 pct second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 nominal at 150 pct third location
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Frequency In Hertz
60.0
-
Thread Series Designator
unc
-
Terminal Type And Quantity
10 threaded stud
-
Body Style
8c multipole-multiple actuator type
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Body Width
2.990 inches minimum and 3.010 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Mounting Surface To Terminal End Distance
3.001 inches minimum and 3.125 inches maximum
-
Pole Quantity
4
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Circuit Protection Type
overcurrent all locations