AM3336HHHEMG6

Circuit Breakers

CIRCUIT BREAKER

AM3336HHHEMG6

5925-00-422-1198

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Time Per Pole In Seconds

    60.000 maximum all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    relay trip fourth location

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    series trip third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 nominal at 150 pct first location

  • Switch Terminal Type

    turret

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Test Data Document

    17773-11207114 drawing

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc fourth location

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc fourth location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac second location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc fourth location

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    instantaneous and time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    4 toggle

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Auxiliary Switch Function And Quantity

    3 control

  • Internal Trip Release Configuration

    series trip first location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 nominal at 150 pct fourth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 nominal at 150 pct second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 nominal at 150 pct third location

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    10 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    3.001 inches minimum and 3.125 inches maximum

  • Pole Quantity

    4

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...