5016669-16

Circuit Breakers

CIRCUIT BREAKER

5016669-16

5925-00-426-8850

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Bushing Length

    0.381 inches minimum and 0.401 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    2.240 inches minimum and 2.260 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Thread Quantity Per Inch

    27

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 24.0 dc single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    2 tab, solder lug

  • Inclosure Protection Type For Which Designed

    waterproof and dustproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.146 inches minimum and 1.166 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    30.0 ac single location and 30.0 dc single location

  • Body Width

    0.553 inches minimum and 0.573 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Unpackaged Unit Weight

    0.062 pounds

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Body Length

    1.803 inches minimum and 1.823 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...