202-29200-35

Switches

SWITCH,ROTARY

202-29200-35

5930-00-429-7110

5930 - Switches

Triumph Aerostructures Llc

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Hazardous Locations/Environmental Protection

    explosion proof

  • First Flat Length

    0.230 inches minimum single actuator and 0.270 inches maximum

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.251 inches maximum

  • Shaft Length

    0.834 inches minimum single actuator and 0.914 inches maximum

  • Nonturn Device Radius

    0.360 inches minimum at 3:00 o'clock and 0.390 inches maximum

  • Individual Section Quantity

    6

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Pole Quantity

    1 each section front

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Contact Switching Action

    breaks before makes 3rd section rear

  • Contact Switching Action

    breaks before makes 4th section rear

  • Contact Switching Action

    makes before breaks 6th section rear

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Contact Load Current Rating

    2.0 amperes resistive load ac at sea level and 1.0 amperes inductive load

  • Thread Series Designator

    unef single mounting facility

  • Mounting Method

    threaded bushing single mounting facility

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Shaft Flat/Slot Angular Location

    180.0 degrees from contact position 1 single actuator

  • Rotor Through Connection Quantity

    1 each section

  • Switch Actuator Indexing Position Quantity

    7 single actuator

  • Shaft Type

    round, flatted single actuator

  • Terminal Type

    tab, solder lug

  • Contact Switching Action

    breaks before makes 1st section rear

  • Contact Switching Action

    breaks before makes 2nd section rear

  • Contact Switching Action

    breaks before makes 5th section rear

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Contact Load Current Rating

    1.0 amperes inductive load dc at sea level

  • Style Designator

    9 tap, circular, bushing mount

  • Throw Quantity

    7 each section rear

  • Operating Temp Range

    -65.0 to 85.0 deg celsius

  • Nonturn Device Type

    tab at 3:00 o'clock

  • Overall Diameter

    1.155 inches minimum and 1.185 inches maximum

  • Flat Height

    0.215 inches minimum single actuator and 0.223 inches maximum

  • Overall Length

    3.819 inches minimum and 3.965 inches maximum

  • Thread Length

    0.417 inches minimum single mounting facility and 0.457 inches maximum

  • Thread Class

    2a single mounting facility

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...