6090703-2
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
6090703-2
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
27 rectangular terminal/terminals on two surfaces
-
Body Material
metal
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference
-
Functional Terminal Type And Quantity
1 threaded stud ground
-
Functional Terminal Type And Quantity
1 connector, receptacle input
-
Mounting Facility Type And Quantity
4 threaded hole
-
Mounting Facility Screw Thread Series Designator
unc
-
Input Terminal Manufacturer Code
96906
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Operating Current Rating Per Function In Amps
1.7 3rd radio interference
-
Operating Current Rating Per Function In Amps
1.7 2nd radio interference
-
Operating Current Rating Per Function In Amps
1.7 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.310 inches nominal
-
Body Height
2.000 inches nominal
-
Body Length
4.000 inches maximum
-
Overall Height
2.460 inches maximum
-
Overall Length
4.500 inches nominal
-
Unpackaged Unit Weight
1.500 pounds
-
Maximum Dielectric Withstanding Dc Voltage
400.0 volts at sea level
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference
-
Functional Terminal Type And Quantity
3 threaded stud output
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Inclosure Type
hermetically sealed
-
Maximum Temp Rise
25.0 deg celsius
-
Input Terminal Identification
ms27478y12d98p
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Average Life Rating In Hours
5000.0
-
Operating Temp Range
-55.0 to 100.0 deg celsius
-
Unthreaded Mounting Hole Diameter
0.166 inches nominal
-
Body Width
2.000 inches maximum