AS33201

Circuit Breakers

CIRCUIT BREAKER

AS33201

5925-00-431-3255

5925 - Circuit Breakers

Society Of Automotive Engineers Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.250 inches nominal

  • Inclosure Protection Type For Which Designed

    vibration resistant and salt spray proof and shock resistant and corrosion resistant and dusttight and fungus resistant and moisture resistant and explosion proof

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Body Length

    0.781 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Specification/Standard Data

    96906-ms3320 government standard

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Center To Center Distance Between Terminals Parallel To Length

    0.500 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Unpackaged Unit Weight

    0.055 pounds

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 2500.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    un

  • Body Width

    0.593 inches maximum

  • Case Material

    plastic

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...