WC375/18-009

Circuit Breakers

CIRCUIT BREAKER

WC375/18-009

5925-00-433-1966

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance re

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac all locations

  • Boss Height

    0.125 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 maximum at 200 pct all locations

  • Specification/Standard Data

    81348-w-c-375/18 government specification

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Body Length

    6.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Body Height

    3.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.000 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Body Width

    2.750 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...