2662530

Circuit Breakers

CIRCUIT BREAKER

2662530

5925-00-433-4123

5925 - Circuit Breakers

Navair And Navsea Managed

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.031 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    150.000 minimum at 125 pct all locations and 500.000 maximum at 125 pct and 80.000 minimum at 150 pct and 300.000 maximum at 150 pct and 35.000 minimum at 200 pct and 125.000 maximum at 200 pct and 12.000 minimum at 300 pct and 135.000 maximum at 300 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Frequency In Hertz

    60.0 all locations

  • Thread Series Designator

    unc

  • Body Length

    3.719 inches nominal

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    3.052 inches nominal

  • Boss Height

    0.156 inches nominal

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    440.0 ac all locations

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Nominal Thread Size

    0.138 inches

  • ~1

    and 6.000 minimum at 400 pct and 18.000 maximum at 400 pct

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...