31-000-0276

Circuit Breakers

CIRCUIT BREAKER

31-000-0276

5925-00-434-4363

5925 - Circuit Breakers

Delta Energy Systems Germany Gmbh

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic-hydraulic single location

  • Internal Trip Release Configuration

    series trip single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Switch Contact Arrangement

    single pole, double throw

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 single location

  • Trip Release Characteristic

    instantaneous single location

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Switch Terminal Type

    tab, solder lug

  • Boss Height

    0.218 inches nominal

  • Reset Method

    manual

  • Terminal Type And Quantity

    2 threaded stud

  • Mounting Surface To Terminal End Distance

    3.609 inches nominal

  • Body Style

    single pole type

  • Switch Location And Position Designation

    external at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc single location

  • Thread Series Designator

    unc

  • Case Material

    plastic

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    4.750 inches nominal

  • Switch Current Rating And Type In Amps

    1.0 dc

  • Auxiliary Switch Function And Quantity

    1 control

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Time Per Pole In Seconds

    0.050 nominal single location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes dc single location

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Body Width

    1.025 inches nominal

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Actuator Position Designation

    at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...