7276-101-7 1/2

Circuit Breakers

CIRCUIT BREAKER

7276-101-7 1/2

5925-00-434-9101

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.850 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.560 inches nominal

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches nominal

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations and 30.0 dc all locations

  • Thread Series Designator

    unc and uns

  • Body Height

    2.765 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Bushing Length

    0.281 inches nominal

  • Actuator Position Designation

    at pole two

  • Nominal Thread Size

    0.138 inches and 0.469 inches

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Thread Quantity Per Inch

    32 and 32

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations and 7.5 amperes dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations and 500.0 dc all locations

  • Frequency In Hertz

    400.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.841 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole and 1 threaded bushing

  • Terminal Type And Quantity

    6 tab w/screw

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...