711505-1
Circuit Breakers
CIRCUIT BREAKER
711505-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
6 threaded stud
-
Thread Series Designator
unc
-
Frequency In Hertz
400.0 all locations
-
Internal Trip Release Configuration
series trip all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Actuator Position Designation
at each pole
-
Manual Actuator Type And Quantity
3 toggle
-
Trip Release Method
magnetic all locations
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
-
Maximum Continuous Load Current Rating Per Pole
65.0 amperes ac all locations
-
Special Handling Feature
magnetic
-
Center To Center Distance Between Terminals Parallel To Width
1.021 inches minimum and 1.041 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
3.053 inches minimum and 3.073 inches maximum
-
Case Material
plastic
-
Body Width
3.042 inches minimum and 3.062 inches maximum
-
Body Style
8c multipole-multiple actuator type
-
Unpackaged Unit Weight
1.770 pounds
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.250 minimum at 200 pct all locations and 0.700 maximum at 200 pct
-
Nominal Thread Size
0.138 inches
-
Actuator Function
trip-reset
-
Main Contact Tripping Mechanism Type
trip free
-
Reset Method
manual
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Trip Release Characteristic
time delay all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Thread Quantity Per Inch
32
-
Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
6 threaded hole
-
Arc Quenching Method
magnetic blowout
-
Pole Quantity
3
-
Mounting Surface To Terminal End Distance
3.239 inches nominal
-
Boss Height
0.146 inches minimum and 0.166 inches maximum
-
Fragility Factor
moderately rugged
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.021 inches minimum and 1.041 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
-
Body Length
3.709 inches minimum and 3.729 inches maximum