AP-12-1-61-251

Circuit Breakers

CIRCUIT BREAKER

AP-12-1-61-251

5925-00-436-0803

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Frequency In Hertz

    50.0 or b60.0

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct and 0.550 maximum at 200 pct

  • Nominal Thread Size

    0.375 inches

  • Actuator Position Designation

    between pole one and two

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes ac

  • Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.109 inches minimum and 0.171 inches maximum

  • Nonturn Device Length

    ab0.063 and ac0.125

  • Nonturn Device Radius

    0.594 inches minimum and 0.656 inches maximum

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Case Material

    metal

  • Body Length

    1.500 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Internal Trip Release Configuration

    series trip

  • Actuator Function

    trip-reset

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Pole Quantity

    2

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Body Width

    1.250 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Body Style

    multipole-single actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...