B4524-7398-3

Circuit Breakers

CIRCUIT BREAKER

B4524-7398-3

5925-00-436-3454

5925 - Circuit Breakers

Trane U.s. Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Body Width

    2.245 inches minimum and 2.255 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.745 inches minimum and 0.755 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.300 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Case Material

    plastic

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Terminal Type And Quantity

    6 tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    1.835 inches minimum and 1.845 inches maximum

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...