A17485
Coils and Transformers
TRANSFORMER,POWER
A17485
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Class
2a
-
Thread Direction
right-hand
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.422 inches minimum and 1.454 inches maximum
-
Frequency Rating
400.0 hertz nominal
-
Body Width
1.837 inches minimum and 2.062 inches maximum
-
Body Height
2.937 inches minimum and 3.125 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Mounting Method
threaded stud
-
Winding Function And Quantity
1 primary and 3 secondary
-
Thread Quantity Per Inch
32
-
Winding Operating Current
250.0 milliamperes ac maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Winding Operating Voltage
26.00 ac volts nominal
-
Thread Series Designator
unc
-
Terminal Type And Quantity
10 tab,solder lug
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.672 inches minimum and 1.704 inches maximum
-
Input-Output Phase Relationship
single phase to single phase
-
Winding Shielding Method
internal shield grounded to core and brought out to terminal
-
Body Length
2.287 inches minimum and 2.312 inches maximum
-
Nominal Thread Size
0.138 inches
-
Winding Tap Location
center tap
-
Winding Operating Current
300.0 milliamperes ac maximum
-
Winding Operating Current
6.0 amperes ac maximum
-
Winding Operating Voltage
15.00 ac volts nominal
-
Winding Operating Voltage
4.00 ac volts nominal