A3921

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

A3921

5915-00-440-7272

5915 - Filters and Networks

Mtk Electronics Inc.

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Type

    hermetically sealed

  • Input Terminal Manufacturer Code

    0c864

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Maximum Voltage Drop Per Function

    1.15 volts ac 1st radio interference

  • Operating Current Rating Per Function In Amps

    10.0 6th radio interference

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Temp Range

    -55.0/+85.0 deg celsius

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Maximum Voltage Drop Per Function

    1.15 volts ac 2nd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Nominal Thread Size

    0.190 inches

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Style Designator

    rectangular terminal/terminals on two surfaces

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 4th radio interference 4th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Mounting Facility Screw Thread Series Designator

    unc

  • Maximum Voltage Drop Per Function

    0.28 volts dc 3rd radio interference

  • Maximum Voltage Drop Per Function

    0.28 volts dc 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Maximum Voltage Drop Per Function

    0.28 volts dc 5th radio interference

  • Mounting Slot Width

    0.500 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Functional Terminal Type And Quantity

    16 tab, solder lug output 2nd function

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Overall Length

    7.250 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 5th radio interference 5th function

  • Operating Current Rating Per Function In Amps

    1.0 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 6th radio interference 6th function

  • Functional Terminal Type And Quantity

    1 connector, plug input 1st function

  • Operating Current Rating Per Function In Amps

    15.0 5th radio interference

  • Body Height

    1.813 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Mounting Facility Type And Quantity

    1 slot

  • Input Terminal Identification

    sma connector plug

  • Overall Height

    1.969 inches nominal

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Body Length

    5.375 inches nominal

  • Operating Current Rating Per Function In Amps

    1.0 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 3rd radio interference 3rd function

  • Body Width

    3.000 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Special Features

    sixteen filtered functions

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...