0154-1-3096-14
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
0154-1-3096-14
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
15942-0154-1-3096 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Function And Quantity
1 primary, fixed autotransformer type single component
-
Overall Diameter
0.315 inches maximum
-
Frequency Rating
25.0 megahertz nominal single component
-
Terminal Type And Quantity
3 wire lead
-
Mounting Method
terminal single group
-
Coil Form Type
solid single component
-
Reliability Indicator
not established
-
Winding Conductor Size
0.02010 inches american wire gage single component single primary output
-
Rating Method
electrical single component single primary output
-
Inductance Rating
0.30 microhenries minimum single component single primary output and 0.30 microhenries minimum single component single primary input and 0.35 microhenries maximum single component single primary output
-
Winding Conductor Size
0.02010 inches american wire gage single component single primary input
-
Hazardous Locations/Environmental Protection
moisture resistant
-
Inductance Rating
0.35 microhenries maximum single component single primary input
-
Inclosure Type
fully inclosed
-
Rating Method
electrical single component single primary input
-
Body Length
0.185 inches maximum