7MC3-4-3

Circuit Breakers

CIRCUIT BREAKER

7MC3-4-3

5925-00-450-0137

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.615 inches minimum and 0.635 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 2.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    0.529 inches minimum and 0.591 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Auxiliary Switch Function And Quantity

    1 control

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.469 inches

  • Bushing Length

    0.280 inches minimum and 0.300 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.623 inches minimum and 1.653 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Switch Terminal Type

    pin

  • Switch Contact Arrangement

    single pole, single throw, normally open

  • Body Style

    single pole type

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.735 inches minimum and 1.765 inches maximum

  • Inclosure Protection Type For Which Designed

    vibration resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.