LHH9174

Circuit Breakers

CIRCUIT BREAKER

LHH9174

5925-00-450-6275

5925 - Circuit Breakers

Defense Electronics Supply Center

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 minimum at 200 pct all locations and 3000.000 maximum at 200 pct all locations

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    8.750 inches nominal

  • Actuator Function

    trip-reset

  • Unthreaded Mounting Hole Diameter

    0.406 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Length

    10.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.625 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Surface To Terminal End Distance

    0.406 inches nominal

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Body Width

    5.000 inches nominal

  • Boss Height

    0.188 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.625 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...