2638051-144

Circuit Breakers

CIRCUIT BREAKER

2638051-144

5925-00-453-5891

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Circuit Protection Type

    overcurrent all locations

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Pole Quantity

    2

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Switch Terminal Type

    wire hook

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Criticality Code Justification

    feat

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Nonturn Device Radius

    0.336 inches nominal

  • Trip Release Method

    magnetic all locations

  • Terminal Type And Quantity

    4 wire hook

  • Switch Contact Arrangement

    single pole, double throw

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Special Features

    poseidon material

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    1.562 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Switch Location And Position Designation

    internal at each pole

  • Switch Current Rating And Type In Amps

    0.5 dc

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Body Width

    1.281 inches maximum

  • Auxiliary Switch Function And Quantity

    1 control

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...