SP-51
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
SP-51
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Iii Maximum Operating Temp
130.0 deg celsius
-
Winding Function And Quantity
1 primary and 1 secondary single component
-
Terminal Type And Quantity
5 wire lead
-
Body Height
0.475 inches maximum
-
(Non-Core Data) Winding Tap Location
center tap
-
Mounting Method
terminal single group
-
Maximum Transformer Power Rating
50.0 milliwatts single component
-
Reliability Indicator
not established
-
Iii Transformer Function
line
-
Primary To Secondary Turn Ratio
1-11/50 to 1 single component
-
Body Width
0.310 inches maximum
-
Winding Operating Current
4.0 milliamperes dc maximum single component single primary
-
Frequency Rating
100.0 hertz minimum and 100.0 kilohertz maximum single component
-
Inclosure Type
fully inclosed
-
Impedance Rating In Ohms
900.0 nominal single component single primary 600.0 nominal single component single secondary
-
Body Length
0.410 inches maximum
-
Test Data Document
07690-417137 drawing