MIS-13685/27

Coils and Transformers

REACTOR

MIS-13685/27

5950-00-456-1768

5950 - Coils and Transformers

U S Army Aviation And Missile

REACTOR

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Winding Operating Current

    15.0 amperes maximum of standard range b and better drop siding single component single winding

  • Inclosure Type

    fully inclosed

  • Mounting Method

    unthreaded hole single group

  • Winding Quantity

    1 single component

  • Body Length

    1.870 inches minimum and 1.900 inches maximum

  • Mounting Facility Quantity

    1 single group

  • Inductance Type

    fixed

  • Body Width

    1.620 inches minimum and 1.650 inches maximum

  • Terminal Type And Quantity

    2 threaded stud

  • Mounting Hole Diameter

    0.175 inches nominal single group

  • Body Height

    0.750 inches minimum and 0.780 inches maximum

  • Overall Length

    2.570 inches minimum and 2.600 inches maximum

  • Frequency Rating

    10.0 kilohertz nominal single component

  • Inductance Rating

    1000.00 millihenries nominal single component single winding

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.